A heat pump that blows cool air for a few minutes while steam rises from a frosty outdoor coil is usually in defrost mode, and that is normal. Air that stays cool, ice that remains after the cycle ends, or a unit that keeps cycling into defrost points to a fault that needs a technician. Bienvenu Brothers repairs and maintains heat pumps in Metairie, New Orleans and the surrounding communities. Our BBB A+ Rated, 4th generation family-owned company is 100% recommended on Facebook and an Angi Super Service Award winner. We are fully licensed (LMP#7214WSPS), stay fully insured and have served South Louisiana since 1937. Contact Bienvenu Brothers or call (504) 835-7783 if the air stays cool.
This guide explains why a heat pump frosts over, how long defrost lasts, why heat pump air can feel cool even when nothing is wrong, what is not normal, what you can check yourself and what Metairie and New Orleans winters mean for your outdoor unit.
Why a Heat Pump Frosts Over and What Defrost Mode Does
In winter, the outdoor coil of a heat pump runs about 10 to 20°F colder than the outdoor air, according to Trane. The cold coil collects moisture from the air the way a cold drink glass collects condensation, and when the coil is cold enough, that moisture freezes and can block airflow.
The outdoor air does not have to be freezing. Trane says defrost can start when it is in the low 40s outside, and it becomes more common in the 20s and 30s. To clear the ice, the reversing valve reverses refrigerant flow so the outdoor coil warms up, which means the heat pump briefly runs in cooling mode. When the ice melts, the system returns to heating.
That matters in the Gulf South. Defrost can begin in the low 40s, so a heat pump here can defrost during an ordinary cold spell and not only during a hard freeze. The National Weather Service’s New Orleans Airport January records show the coldest January averaged 43.4°F, in 1977, and its arctic outbreak history records a low of 20°F on January 17, 2018, which falls in the range where Trane says defrost is more common.
How Long Does Defrost Last? What the Manufacturers Say
Three manufacturers publish three different ranges. The table puts them side by side.
| Source | Typical defrost cycle | Notes |
|---|---|---|
| Trane | Usually 3 to 5 minutes | Trane uses sensors and defrosts only when needed (demand defrost) and ends the cycle as soon as the ice clears. It says some competitors use timed defrost that runs for a fixed period. |
| Carrier | About 5 to 10 minutes | Carrier calls a frost layer under 1/4 inch generally acceptable and says defrost that occurs unusually often is a reason to call a professional. |
| Lennox | About 5 to 15 minutes | Lennox says units may defrost on demand or on a 30, 60 or 90 minute timer, and that the system blows cooler air during the cycle. |
The ranges differ because the controls differ. A demand control watches for ice and stops as soon as it clears, and a timed control runs a fixed period on a fixed schedule. A cycle of up to about 15 minutes sits inside the published ranges. Cycles that keep getting longer, defrost that seems to run constantly or frost that starts to cover the whole unit are the signs Trane lists for a service call.
Why Heat Pump Air Feels Cool Even When Nothing Is Wrong
A heat pump moves heat and does not burn fuel, so its supply air is warmer than your room but cooler than furnace air. Two sources give benchmarks, and they differ a little.
| Source | Heat pump supply air in heating mode | Gas furnace supply air |
|---|---|---|
| Energy Vanguard | Usually 90 to 110°F | About 125°F at the vents, and about 150°F at the heat exchanger |
| Carrier | About 85 to 100°F | About 120 to 140°F |
By Energy Vanguard’s figures, heat pump air runs roughly 15 to 35°F cooler than furnace air at the vents (125 minus 110 is 15, and 125 minus 90 is 35). Air at 90 to 110°F is still warmer than a 70°F room, yet it can feel cool when it blows across your skin, and the Energy Vanguard article notes that air blown directly at occupants can feel cold.
Several things push supply air lower. Energy Vanguard lists duct leakage, poorly insulated ducts, high airflow, system sizing, installation quality and defrost cycles, and Carrier says duct leaks can lose about 20 to 30% of the air moving through a duct system. A simple test uses a probe or kitchen thermometer at a supply register after the system has been heating for several minutes and is not in defrost. A reading near the benchmark means the system is making heat, and a reading near room temperature means it is not. Our post on why a heat pump runs constantly and still does not warm the home covers what to check when the readings fall short.
Normal or Not? What You See, Hear and Feel
Use this table to sort what you notice at the outdoor unit and at the vents.
| What you notice | Usually normal? | What it means | What to do |
|---|---|---|---|
| A thin layer of frost that clears within minutes | Yes | Moisture froze on a coil that runs colder than the air. Carrier calls a layer under 1/4 inch generally acceptable. | Watch that it clears |
| A cloud of steam from the outdoor unit | Yes | The steam is melted ice evaporating during defrost, according to Trane. | Nothing |
| The outdoor fan stops and you hear a swoosh | Yes | The reversing valve is switching refrigerant direction, according to Trane. | Nothing |
| Cooler air from the vents for several minutes, or AUX on the thermostat | Yes | Defrost is running, and electric strip heat may be covering. | Wait for the cycle to end |
| Air that is warm but cooler than a furnace | Yes | Typical heat pump supply air. | Nothing |
| Ice thicker than 1/4 inch, or ice that remains after defrost ends | No | Carrier links this to restricted airflow, low refrigerant or a defrost system problem. | Turn the system off at the thermostat and call |
| Frost covering the unit, or defrost that runs constantly or keeps getting longer | No | Trane lists these as reasons to call a dealer. | Call |
| Cool air well beyond a defrost cycle, or a room 2 to 3°F or more from the setting | No | Carrier advises a service call when the indoor temperature stays that far from the thermostat setting. | Check the thermostat, filter and breakers, then call |
| Good cooling but no heating | No | Carrier says the reversing valve may be stuck. | Call, because the repair needs a professional |
| Breakers that keep tripping | No | Carrier says to call a professional if they keep tripping. | Reset once, then call |
What Causes a Heat Pump to Blow Cold Air
The cause is often simple, and the table puts the simple checks first.
| Cause | How it shows up | First check |
|---|---|---|
| Thermostat set to cool, or fan on constant | Cool air from the vents, and Carrier lists both settings among the causes | Set the thermostat to heat and the fan to auto |
| Tripped breaker or switched-off disconnect | The indoor or outdoor unit is not running, and Carrier notes both units have separate breakers | Check both breakers, the outdoor disconnect and the air handler switch |
| Clogged filter | Weak airflow and lukewarm air, according to Carrier | Replace the filter |
| Debris or poor clearance around the outdoor unit | Restricted airflow and more ice. Carrier suggests at least 24 inches of clear space, and Lennox suggests two feet | Clear leaves and growth from the unit |
| Frozen outdoor coil | Ice thicker than 1/4 inch, or ice that stays after defrost | Switch the system off and call |
| Leaky or uninsulated ducts | Lukewarm air in some rooms, and Carrier says duct leaks can lose about 20 to 30% of the air | Look for disconnected ducts you can reach, then ask for a duct check |
| Low refrigerant | The unit cannot keep up, or the coil freezes, according to Carrier | Call, because refrigerant work needs a certified technician |
| Stuck reversing valve | Normal cooling but no heating | Call |
| Defrost control or sensor fault | Ice stays after defrost, or defrost runs too often | Call |
| Furnace not firing during defrost | Cool air for the length of the cycle in a dual-fuel system, which Trane calls normal | Ask how your switchover is set up |
| Wind across the outdoor coil | The Department of Energy says high winds can cause defrosting problems | Ask about a windbreak on the upwind side |
Heat Pump Blowing Cold Air: DIY or Professional?
Homeowners can handle the settings, the filter and the clearance. Refrigerant and electrical work belongs to a licensed technician.
| Task | Reasonable for a homeowner | Call a professional when |
|---|---|---|
| Set the thermostat to heat and the fan to auto | Yes | The thermostat shows an error or stays blank |
| Replace the filter | Yes | The filter is clean and the air stays cool |
| Clear leaves, grass and growth from the outdoor unit | Yes | Debris is packed into the coil fins |
| Check breakers and switches, and reset a breaker once | Yes | A breaker trips again |
| Wait out a defrost cycle | Yes | The cycle never seems to end, or ice remains afterward |
| Chip, scrape or pry ice off the coil | No | Always, because tools can damage the fins and refrigerant lines |
| Add or check refrigerant | No | Always. EPA’s Section 608 program requires certification for technicians who maintain, service, repair or dispose of covered equipment |
| Repair a reversing valve, defrost control, sensor or wiring | No | Always. Carrier says complex issues with refrigerants or electrical parts need a professional |
| Open cabinet panels | No | Always. Lennox warns against opening heat pump panels or handling electrical parts beyond resetting a breaker |
What to Do When Your Heat Pump Blows Cold Air, Step by Step
Work through these steps in order. Each one rules out a simple cause before you call.
- Check the thermostat. Confirm it is set to heat with the fan on auto. Lennox suggests raising the setting at least 5 degrees to see whether the system responds, and our guide to making the most of your thermostat settings explains the controls.
- Look at the outdoor unit. Thin frost, steam and a stopped fan point to defrost. Wait about 15 minutes, which covers the longest published cycle.
- Read the thermostat for AUX or EM Heat. AUX means electric strips are helping, which is expected during defrost. If EM Heat shows, or AUX stays on for long periods, plan to call.
- Replace the filter. Carrier suggests checking it every 60 to 90 days, and Lennox suggests every 1 to 3 months.
- Check the breakers and switches. Carrier describes a reset: turn off the thermostat, switch both breakers off for one minute, switch them back on and wait a few minutes before setting the thermostat to heat. After a storm, our guide to resetting a heating system after a power outage covers more.
- Clear the outdoor unit. Remove leaves and debris, and keep at least two feet of clear space around the unit.
- Decide. If ice is thicker than 1/4 inch, ice remains after defrost or the air stays cool after these checks, turn the system off at the thermostat and call (504) 835-7783.
AUX, Emergency Heat and Dual-Fuel Systems
Many heat pump thermostats show AUX or EM Heat. AUX means the electric heat strips are helping or covering, as Trane describes for defrost. EM Heat is a manual emergency setting, and Carrier advises using it sparingly because electric resistance heat alone uses far more electricity than normal heat pump operation.
Strip heat also explains an odd smell. The strips collect dust over the summer, and they can smell the first time they run, which may be on the first cold morning and not on the first day of heat. Our post on a burning smell when you first turn on the heat explains what is normal.
Homes that pair a heat pump with a gas furnace behave differently. Trane notes that dual-fuel systems where the furnace does not fire with the heat pump may blow cool air during defrost, and it calls that normal. Our guide to dual-fuel systems explains how the two work together.
How to Prevent Frost Problems
- Keep the outdoor unit clear. Lennox suggests at least two feet of clearance, and Carrier suggests 24 inches. Remove leaves and debris after storms.
- Replace the filter on schedule. Carrier suggests every 60 to 90 days, and Lennox suggests every 1 to 3 months.
- Schedule service twice a year. Lennox recommends professional tune-ups twice a year, and a heat pump works in both seasons. The Department of Energy advises leak-checking refrigeration systems at installation and during each service call.
- Protect the unit from wind. The Department of Energy says outdoor units should be protected from high winds, which can cause defrosting problems, and that a bush or fence upwind of the coils can block the wind.
- Choose demand defrost when you replace a unit. The Department of Energy recommends a demand-defrost control because it reduces unnecessary defrost cycles.
- Watch start-up behavior. Our post on how refrigerant migration causes start-up struggles in heat pumps explains one pattern that shows up after long idle periods.
Frost and Defrost in Metairie, New Orleans and Nearby Communities
Four local factors shape how often your heat pump defrosts. The table shows what each one means for your outdoor unit.
| Local factor | What the data shows | What it means for your heat pump |
|---|---|---|
| Winter temperatures | The National Weather Service’s New Orleans Airport January records, kept since 1947, show the coldest January averaged 43.4°F, in 1977. Its arctic outbreak history records a low of 20°F on January 17, 2018. | Trane says defrost can start in the low 40s and is more common in the 20s and 30s, so defrost is a normal part of Gulf South cold spells. |
| Humidity and rain | LSU AgCenter places most of Louisiana in the hot, humid climate region and reports that New Orleans averages 62 inches of rain a year. | The coil collects moisture from damp air, so cold, damp mornings give it plenty to freeze. |
| Heating fuel | The Energy Information Administration’s 2020 survey shows 62% of Louisiana homes use electricity as the main heating fuel and 33% use natural gas. | Electric heat and heat pumps are the main heat for most homes here, and gas homes with a dual-fuel setup behave differently during defrost. |
| Wind | The Department of Energy says outdoor units should be protected from high winds, which can cause defrosting problems. | Ask your technician whether a windbreak on the upwind side suits your unit and its clearances. |
We repair and maintain heat pumps on both banks of Jefferson Parish and across Orleans Parish. Choose the community nearest you:
- Metairie, LA
- New Orleans, LA
- Kenner, LA
- Harahan, LA
- River Ridge, LA
- Gretna, LA
- Harvey, LA
- Marrero, LA
- Westwego, LA
Heat Pump Cold Air and Frost FAQs
These are the questions Metairie and New Orleans homeowners ask us most often about heat pumps that blow cold air or freeze over.
Why is my heat pump blowing cold air when it is set to heat?
The most common harmless reason is defrost mode. Carrier calls cool air during defrost a normal function, and Trane explains that the reversing valve briefly runs the system in cooling mode to melt ice. Other causes are a thermostat set to cool or the fan on constant, a tripped breaker, a clogged filter, a blocked outdoor coil, low refrigerant and a stuck reversing valve. Start with the thermostat, filter and breakers, and call (504) 835-7783 if the air stays cool.
Is it normal for a heat pump to freeze up in winter?
A thin layer of frost that clears during defrost is normal. Trane says the outdoor coil runs 10 to 20°F colder than the outdoor air, collects moisture and can freeze, and defrost can begin when it is in the low 40s outside. Carrier considers a frost layer under 1/4 inch generally acceptable, and it says ice thicker than that, or ice that remains after defrost, is not normal. Call us if the unit stays iced over.
How long does a heat pump defrost cycle last?
Published ranges differ by control type. Trane says its demand defrost cycles usually last 3 to 5 minutes, Carrier gives about 5 to 10 minutes and Lennox gives about 5 to 15 minutes. Trane lists defrost cycles that keep getting longer, or a heat pump that seems to be constantly switching into defrost, as reasons to call a dealer.
Why is steam coming off my outdoor heat pump unit?
Steam during defrost is normal. Trane explains that it is melting ice evaporating from the warmed coil. You may also see the outdoor fan stop and hear a swooshing sound as the refrigerant reverses direction. If ice remains after the steam clears, call us.
How warm should heat pump air be?
Energy Vanguard puts typical heat pump supply air at 90 to 110°F, and Carrier cites about 85 to 100°F. Gas furnace air at the vents runs about 125°F according to Energy Vanguard and 120 to 140°F according to Carrier. Heat pump air is warmer than the room but cooler than furnace air, so it can feel cool on your skin. Carrier advises a service call if the indoor temperature stays more than 2 to 3°F from the thermostat setting.
What do AUX and EM Heat mean on my thermostat?
AUX means auxiliary heat, and Trane notes it appears when electric heat strips are keeping the home warm, for example during defrost. EM Heat is a manual emergency heat setting. Carrier advises using emergency heat sparingly, because electric resistance heat alone uses far more electricity than normal heat pump operation. If AUX or EM Heat stays on for long periods, call us.
How much ice on a heat pump is too much?
Carrier says ice thicker than 1/4 inch, or ice that remains after defrost, is not normal and may point to restricted airflow, low refrigerant or a defrost system problem. Trane lists frost and ice that start to cover the unit as a reason to call a dealer. Turn the system off at the thermostat and call us.
Should I chip the ice off my heat pump?
No. Do not use tools to chip or scrape ice, because the coil fins and refrigerant lines are easy to damage. Lennox warns against opening heat pump panels or touching refrigerant lines. Turn the system off at the thermostat and call (504) 835-7783, so a technician can find out why the ice formed and repair the cause.
Why does my heat pump blow cool air on cold mornings or at night?
Cold, damp weather gives the coil the most moisture to freeze, so defrost runs more often then. Trane says defrost is more common when it is in the 20s and 30s outside, and it calls cooler air from the vents during defrost normal for systems without backup heat. Our post on why heat pumps feel less powerful at night explains another common pattern. If the air stays cool after defrost ends, call us.
Can a dirty filter make a heat pump blow cold air?
Yes. Carrier says a clogged filter restricts airflow and can cause the system to shut down or blow lukewarm air, and it suggests checking the filter every 60 to 90 days. Lennox suggests every 1 to 3 months, and more often with pets or allergies. Replace the filter first, and call us if the air stays cool.
Could low refrigerant cause cold air or ice?
Yes. Carrier lists low refrigerant among the causes when the unit cannot keep up or the coil freezes. Refrigerant work belongs to a certified technician, because EPA requires technicians who maintain, service, repair or dispose of equipment containing regulated refrigerants to pass an EPA-approved test for Section 608 certification. The Department of Energy adds that refrigeration systems should be leak-checked at installation and during each service call.
What does a stuck reversing valve do?
The reversing valve switches the system between heating and cooling, and it reverses refrigerant flow for defrost. Carrier says that if a unit works well in cooling mode but not in heating, the reversing valve may be stuck, and it says this repair needs a professional. Call us if your heat pump cools but will not heat.
Can a power outage or tripped breaker cause cold air?
Yes. Carrier notes that the outdoor and indoor units have separate breakers, and that the outdoor disconnect and the indoor air handler switch must both be on. After a storm or outage, check both breakers and both switches before you assume the heat pump failed. Call us if a breaker trips again after one reset.
Does a dual-fuel system blow cold air during defrost?
It can. Trane notes that systems without backup heat, and dual-fuel systems where the furnace does not fire with the heat pump, may blow cool air from the vents during defrost, and it calls that normal. Ask us how your switchover is set up if the cool air bothers you.
When should I call Bienvenu Brothers about a heat pump blowing cold air?
Call us when ice stays after defrost, defrost runs constantly or keeps getting longer, the air stays cool well beyond a defrost cycle, the room stays 2 to 3°F or more from the setting or a breaker keeps tripping. Tell us the brand, what the thermostat shows (AUX or EM Heat) and what the outdoor unit is doing. We offer same-day scheduling and 24/7 emergency service. Use our contact page or call (504) 835-7783.
When to Call Bienvenu Brothers About a Heat Pump Blowing Cold Air
Call us when ice stays after defrost, defrost runs constantly, the air stays cool after the simple checks or a breaker keeps tripping. Our licensed technicians test airflow, refrigerant, the reversing valve, the defrost controls and the electrical connections, and explain what they find before any repair begins. Our heat pump service covers ducted, ductless and dual-fuel systems, and our heating repair service covers the backup heat. Call (504) 835-7783 or Contact Bienvenu Brothers to schedule a visit. The table shows what you get when you choose Bienvenu Brothers.
| What We Offer | What It Means for You |
|---|---|
| Fully licensed (LMP#7214WSPS) | A licensed contractor handles your heat pump repair. |
| Fully insured | You stay protected if something goes wrong on your property. |
| BBB A+ Rated | An independent organization rates our business practices and tracks complaints, and you can read the profile yourself. |
| 100% recommended on Facebook | Customers recommend our work in public reviews that anyone can read. |
| Angi Super Service Award winner | Angi recognizes companies that earn consistently high ratings from verified customers. |
| Heat pump service for ducted, ductless and dual-fuel systems | Whatever type of heat pump you own, one team can service it. |
| Same-day scheduling and 24/7 emergency service | Help is available when the air turns cold, whatever the hour. |
| 4th generation, serving since 1937 | Four generations of experience with South Louisiana homes and heating systems. |
| Clear explanations before repairs | We explain what we find and what it means before any work begins. |
Bienvenu Brothers repairs and maintains heat pumps across Metairie, New Orleans and nearby communities. Licensed, fully insured, BBB A+ Rated and available 24/7 for emergencies. Call (504) 835-7783 to schedule a heat pump check.